An effective dose assessment technique with NORM added consumer products using skin-point source on computational human phantom

DH Yoo, WG Shin, HC Lee, HJ Choi, M Testa… - Applied Radiation and …, 2016 - Elsevier
… to the source location, the organ equivalent doses were … −17 cm to 15 cm, −10 cm to 12 cm,
0 cm to 20 cm, respectively (… The annual effective dose was calculated in the same gamma

Development of an effective dose coefficient database using a computational human phantom and Monte Carlo simulations to evaluate exposure dose for the usage …

DH Yoo, WG Shin, J Lee, YS Yeom, CH Kim… - Applied radiation and …, 2017 - Elsevier
… The organs near the source location show relative higher doses than the long-distance organs
for the various gamma … the skin but also to the opposite skin by passing through the body. …

Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: results of an international …

C Huet, J Eakins, M Zankl, JM Gómez-Ros… - Radiation …, 2022 - Elsevier
… with a source location translated 2 cm and 5 cm nearer or … , its organs are closer to the
source on average; doses are … detector (10 cm away from the frontal skin) and the source (behind …

Assessment of the absorbed doses in the organs in case of radiation emergency with the sealed gamma-sources

V Golikov - Radiation Protection Dosimetry, 2019 - academic.oup.com
source is in contact with a body of a victim, primarily locateddoses in internal organs, skin
and tissues close to the source … special tissue-equivalent plastic with effective atomic number …

Simulation study of personal dose equivalent for external exposure to radioactive cesium distributed in soil

D Satoh, T Furuta, F Takahashi, C Lee… - Journal of Nuclear …, 2017 - Taylor & Francis
… personal dose equivalent was calculated for a mixed source … tissue-equivalent material
was placed on the body surface of … dose equivalent data measured by survey meters before

Estimation of absorbed gamma dose rate from granite by Monte Carlo simulation approach

J Knežević, P Kuzmanović, D Mrdja… - Journal of …, 2020 - iopscience.iop.org
dose rate values from simulations based on two different thicknesses of concrete wall (10 cm
and 20 cm) can … absorbed dose rate near the surface of the granite sample was found to be: …

IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

M Andersson, L Johansson, K Eckerman, S Mattsson - EJNMMI research, 2017 - Springer
… alpha, beta, and gamma decays were benchmarked against … a density of 1.92 g/cm 3 and a
volume of 10 cm 3 . The absorbed … Before the official SAF values of the ICRP/ICRU reference …

First on-site true gamma-ray imaging-spectroscopy of contamination near Fukushima plant

D Tomono, T Mizumoto, A Takada, S Komura… - Scientific Reports, 2017 - nature.com
… to estimate potential health effects to the human body. The 1-… with a 10 cm × 10 cm × 16 cm
gas volume, based on the 30-cm-… We detected 662-keV gammas from the point source with a …

Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films

N Wen, S Lu, J Kim, Y Qin, Y Huang, B Zhao, C Liu… - Radiation …, 2016 - Springer
… similar light scattering characteristics near the film borders. … with 5 cm thickness on the top
of the film and 10 cm thickness … of points passing gamma based on absolute dose difference …

Estimation of external gamma radiation dose rate for personnel and students in the area of Kasetsart university, Thailand

C Pornnumpa, J Kanchanawarin - Journal of Physics …, 2019 - iopscience.iop.org
10 cm soil layer for 13 samples for investigating the natural background radiation. The gamma
dose rates in air obtained were found … As the university is located near several radiation …